LUTRON DM-9961 Auto Range Multimeter

LUTRON DM-9961 Auto Range Multimeter
Harga Rp 0
Persediaan Ada
Kode Lutron DM-9661
Merk LUTRON

Jumlah Add to Cart

LUTRON DM-9961 Auto Range Multimeter

 

Features

True RMS ACV, ACA measurement.

4000 counts A/D, high resolution.

Meet IEC 1010 CAT III 1000 V safety requirement.

Both 10 A, mA, uA current are build fuse for safety consideration.

Large LCD display with measurement unit.

10 M ohm impedance for voltage circuit.

Multi function measurement. DCV, ACV, DCA,

ACA, Resistance, Capacitance, Frequency, Duty,

Diode, Continuity beeper.

Operates from one DC 9V battery.

Data hold.

Built-in overload protection for most ranges.

Relative measurement.

Uses durable, long-lasting components, enclosed in strong, light weight ABS-plastic housing.

Auto range with manual range selection.

Full line optional adapters : Clamp adapter, Tach

ometer adapter, Pressure adapter, Humidity Adapter, Sound level adapter, Anemometer adapter, Light adapter, EMF adapter.

When make the ACV, ACA measurement, it also can measure the signal frequency, % duty at the same time.

 

Specifications

Display

65 mm x 48 mm large LCD display with bar graph indicator.

Measurement

DCV, ACV, DCA, ACA, Resistance, Capacitance, Frequency, Duty, Diode, Continuity beeper.

A/D counts no.

4000 counts.

Range selection

Auto range with manual range selection.

Special function

Relative measurement, Data hold.

Data hold

To freeze the display reading on the LCD display.

Power On/Off management

Auto power of or manual power off.

Relative measurement

To offset the measurement value.

Polarity

Automatic Switching, " - " indicates negative polarity.

Zero adjustment

Automatic.

Sampling time

Approx. 0.5 to 1 second.

Operating Temp. & Humidity

0 to 50°C, Max. 80% RH.

Power supply

006P DC 9V battery.

Power consumption

Approx. DC 1.7 mA.

Dimension

185 x 88 x 40 mm

Weight

350g

Accessories included

Red and Black Test Leads ( CAT III 1KV Test Leads) x 1 set

0.5 Amp Spare Fuse x 1 pcs

Instruction manual

Optional accessories

Full line adapters :

ACA/DCA current adapter, Tachometer adapter, Humidity adapter, Pressure adapter, Light adapter, EMF adapter, Sound level adapter, High voltage probe.

Soft carrying case CA-05A

 

Electrical Specifications (23± 5C°)

DC Voltage

Capacitance

Range

400.0mV / 4V / 40V / 400V / 1000 V

Range

40 nF/400 nF/4 uF/40 uF/100 uF

Resolution

0.1mV / 1mV / 10mV / 100m V / 1V

Resolution

10 pF/0.1 nF/1 nF/10 nF/0.1 uF

Accuracy

± (0.5%+2d)

Accuracy

± (3%+1d )

Input impedance

10 M ohm.

 

Over load protection

± 500DCV, 350ACV - 200mV range.

± 1000DCV, 1000ACV - other ranges.

AC Voltage ( True RMS )

Frequency

Range

400.0mV / 4V / 40V / 400V / 1000 V

Range

4Hz / 40Hz / 400Hz / 4KHz / 40KHz / 400KHz / 4MHz

Resolution

0.1mV / 1mV / 10mV / 100m V/ 1 V

Resolution

0.001Hz / 0.01Hz / 0.1Hz / 0.001KHz / 0.01 KHz

0.1KHz / 0.001MHz

Accuracy

± (1%+2d ) * Spec. are tested under 50/60Hz

Accuracy

± (0.5%+2d )

Input impedance

10 M ohm.

Sensitivity

Min. 1.5 V rms, Max. 5 V rms.

Over load protection

± 500DCV, 350ACV - 200mV range.

± 1000DCV, 1000ACV - other ranges.

AC Current ( True RMS ) DC Current

Duty

Range

10A / 400mA / 40mA / 4000uA / 400uA

Range

1% to 99%

Resolution

10 mA / 0.1mA / 0.01mA / 1uA / 0.1uA

Resolution

0.1%

Accuracy

400mA / 40mA / 4000uA / 400uA : ±(0.5%+2d )

10A : ± (1.5%+2d )

* ACA spec. are tested under 50/60Hz.

Accuracy

± 1% duty

Over load protection

10A range : 10A fuse.

uA, mA range : 500 mA fuse.

Measuring signal and level

Function switch set to " Hz " : 2 Vp-p to 5 Vp-p, square wave 10 KHz max.

 

Function switch set to "ACV", "ACA" : 50 Hz to 500 Hz

Diode ( Forward voltage, VF )

OHMS

Range

4 V DC.

Range

400 / 4K / 40K / 400K / 4M / 40M ohm

Resolution

0.001 V.

Resolution

0.1 / 1 / 10 / 100 / 1K / 10K ohm

Accuracy

± (0.5%+2d )

Accuracy

400 ohm

4K/40K/400K/4M

± (0.5%+2d )

 

40 M

± (2%+5d )

Over load protection

± 350 DCV, 350 ACV

Continuity Beeper

Beeper will sound if measured resistance less than 20 ohm.

* Appearance and specifications are subject to change without notice